New Jersey Licensed Home
Inspector
NJ License # 24GI00097500
New Jersey Licensed Radon
Technician
NJ Radon License #
MET12706
ASHI Standards PDF
PREFACE
Home Inspection
Home inspection began as a consumer service in the early 1970’s in
direct response to the growing demand by home buyers to learn about
the condition of a house prior to purchase. It is a unique
discipline, distinct from construction, engineering, architecture,
or municipal building inspection, and as such requires its own set
of professional guidelines and qualifications. It was for this
reason that the American Society of Home Inspectors (ASHI®) was
formed in 1976. A home inspection in accordance with ASHI’s®
Standards of Practice helps buyers to make a sound purchasing
decision based on accurate, objective information.
American Society of Home Inspectors
ASHI® is the oldest and most respected professional organization of
home inspectors in North America. Its purpose is to build public
awareness of home inspection and enhance the technical and ethical
performance of professional home inspectors.
Standards of Practice
The ASHI® Standards of Practice guide home inspectors in the
performance of their inspections. They are the most widely accepted
home inspection guidelines in use, and include all of the home’s
major systems and components. The ASHI® Standards of Practice and
Code of Ethics are recognized by many government, professional, and
legal authorities as the definitive standard for professional
performance.
Code of Ethics
The American Society of Home Inspectors’ Code of Ethics stresses the
home inspector’s responsibility to act in a strictly fair,
impartial, and professional manner, and protects consumers from
conflicts of interest.
Inspector Qualifications
Selecting the right home inspector can be as important as finding
the right home. Members of ASHI® have demonstrated their proficiency
by performing no fewer that 250 fee-paid home inspections in
accordance with the ASHI® Standards of Practice; they have also
passed a series of written examinations testing their knowledge of
residential construction, inspection techniques, report-writing, and
ASHI’s® Standards of Practice and Code of Ethics. Membership in the
American Society of Home Inspectors is an earned credential, and the
best evidence of an inspector’s competence and professionalism.
1.0 INTRODUCTION
1.1 The American Society of Home Inspectors, Inc. (ASHI) is a
not-for-profit professional society established in 1976 whose
volunteer membership consists of private, fee-paid home inspectors.
ASHI's objectives include promotion of excellence within the
profession and continual improvement of its member's inspection
services to the public.
1.2 These Standards of Practice:
A. provide inspection guidelines
B. make public the services provided by private fee-paid inspectors
C. define certain terms relating to these inspections
2.0 PURPOSE AND SCOPE
2.1 Inspections performed to these guidelines are intended to
provide the client with a better understanding of the property
conditions, as observed at the time of the inspection.
2.2 Inspectors shall:
A. observe readily accessible installed systems and components
listed in these Standards.
B. submit a written report to the client which shall:
1. describe those components specified to be described in sections
4-12 of these Standards
2. state which systems and components designated for inspection in
these Standards have been
inspected
3. state any systems and components so inspected which were found to
be in need of immediate major
repair
2.3 These Standards are not intended to limit inspectors from:
A. reporting observations and conditions in addition to those
required in Section 2.2
B. excluding systems and components from the inspection if requested
by the client
3.0 GENERAL
LIMITATIONS AND EXCLUSIONS
3.1 General limitations:
A. Inspections done in accordance with these Standards are visual
and are not technically exhaustive.
B. These Standards are applicable to buildings with four or less
dwelling units and their garages or carports.
3.2 General exclusions:
A. Inspectors are NOT required to report on:
1. life expectancy of any component or system
2. the causes of the need for a major repair
3. the methods, materials and costs of corrections
4. the suitability of the property for any specialized use
5. compliance or non-compliance with applicable regulatory
requirements
6. the market value of the property or its marketability
7. the advisability or inadvisability of purchase of the property
8. any component or system which was not observed
9. the presence or absence of pests such as wood damaging organisms,
rodents, or insects
10. cosmetic items, underground items, or items not permanently
installed
B. Inspectors are NOT required to:
1. offer or perform any act or service contrary to law
2. offer warranties or guarantees of any kind
3. offer or perform engineering, architectural, plumbing, or any
other job function requiring an occupational
license in the jurisdiction where the inspection is taking place,
unless the inspector holds a valid
occupational license, in which case he/she may inform the client
that he/she is so licensed, and is
therefore qualified to go beyond the ASHI Standards of Practice, and
for an additional fee, perform
additional inspections beyond those within the scope of the basic
ASHI inspection
4. calculate the strength, adequacy, or efficiency of any system or
component
5. enter any area or perform any procedure which may damage the
property or its components or be
dangerous to the inspector or other persons
6. operate any system or component which is shut down or otherwise
inoperable
7. operate any system or component which does not respond to normal
operating controls
8. disturb insulation, move personal items, furniture, equipment,
plant life, soil, snow, ice, or debris which
obstructs access or visibility
9. determine the presence or absence of any suspected hazardous
substance including but not limited to
toxins, carcinogens, noise, contaminants in soil, water, and air
10. determine the effectiveness of any system installed to control
or remove suspected hazardous
substances
11. predict future conditions, including but not limited to failure
of components
12. project operating costs of components
13. evaluate acoustical characteristics of any system or component
3.3 Limitations and exclusions specific to individual systems are
listed in the following sections.
4.0 SYSTEM: STRUCTURAL COMPONENTS
4.1 The inspector shall observe:
A. structural components including:
1. foundation
2. floors
3. walls
4. columns
5. ceilings
6. roofs
4.2 The inspector shall:
A. describe the type of:
1. foundation
2. floor structure
3. wall structure
4. columns
5. ceiling structure
6. roof structure
B. probe structural components where deterioration is suspected.
However, probing is NOT required when probing
would damage any finished surface
C. enter underfloor crawl spaces and attic spaces except when access
is obstructed, when entry could damage the
property, or when dangerous or adverse situations are suspected.
D. report the methods used to observe underfloor crawl spaces and
attics
E. report signs of water penetration into the building or signs of
abnormal or harmful condensation on building
components.
5.0 SYSTEM: EXTERIOR
5.1 The inspector shall observe:
A. wall cladding, flashings and trim
B. entryway doors and representative number of windows
C. garage door operators
D. decks, balconies, stoops, steps, areaways, and porches including
railings
E. eaves, soffits, and fascias
F. vegetation, grading, drainage, driveways, patios, walkways and
retaining walls with respect to their effect on the
condition of the building
5.2 The inspector shall:
A. describe wall cladding materials
B. operate all entryway doors and representative number of windows,
including garage doors, manually or by using
permanently installed controls of any garage door operator.
C. report whether or not any garage door operator will automatically
reverse or stop when meeting reasonable
resistance during closing
5.3 The inspector is NOT required to observe:
A. storm windows, storm doors, screening, shutters, awnings and
similar seasonal accessories
B. fences
C. safety glazing
D. garage door operator remote control transmitters
E. geological conditions
F. soil conditions
G. recreational facilities
H. outbuildings other than garages and carports
6.0 SYSTEM: ROOFING
6.1 The inspector shall observe:
A. roof coverings
B. roof drainage systems
C. flashings
D. skylights, chimneys and roof penetrations
E. signs of leaks or abnormal condensation on building components
6.2 The inspector shall:
A. describe the type of roof covering materials
B. report the methods used to observe the roofing
6.3 The inspector is NOT required to:
A. walk on the roofing
B. observe attached accessories including but not limited to solar
systems, antennae, and lightning arrestors
7.0 SYSTEM: PLUMBING
7.1 The inspector shall observe:
A. interior water supply and distribution system including:
1. piping materials, including supports and insulation
2. fixtures and faucets
3. functional flow
4. leaks
5. cross connections
B. interior drain, waste and vent system including:
1. traps; drain, waste, and vent piping; piping supports and pipe
insulation
2. leaks
3. functional drainage.
C. hot water systems including:
1. water heating equipment
2. normal operating controls
3. automatic safety controls
4. chimneys, flues, and vents
D. fuel storage and distribution systems including:
1. interior fuel storage equipment, supply piping, venting, and
supports
2. leaks
E. sump pump
7.2 The inspector shall:
A. describe:
1. water supply and distribution piping materials
2. drain, waste, and vent piping materials
3. water heating equipment
B. operate all plumbing fixtures, including their faucets and all
exterior faucets attached to the house.
7.3 The inspector is NOT required to:
A. state the effectiveness of anti-siphon devices
B. determine whether water supply and waste disposal systems are
public or private
C. operate automatic safety controls
D. operate any valve except water closet flush valves, fixture
faucets and hose faucets
E. observe:
1. water conditioning systems
2. fire and lawn sprinkler systems
3. on-site water supply quantity and quality
4. on-site waste disposal systems
5. foundation irrigation systems
6. spas, except as to functional flow and functional drainage
8.0 SYSTEM: ELECTRICAL
8.1 The inspector shall observe:
A. service entrance conductors
B. service equipment, grounding equipment, main overcurrent device,
main and distribution panels
C. amperage and voltage ratings of the service
D. branch circuit conductors, their overcurrent devices, and the
compatibility of their ampacities and voltages
E. the operation of a representative number of installed lighting
fixtures, switches and receptacles located inside the house, garage,
and on its exterior walls
F. the polarity and grounding of all receptacles within six feet of
interior plumbing fixtures, and all receptacles in the
garage or carport, and on the exterior of inspected structures
G. the operation of Ground Fault Circuit Interrupters.
8.2 The inspector shall:
A. describe:
1. service amperage and voltage
2. service entry conductor materials
3. service type as being overhead or underground
4. location of main and distribution panels
B. report any observed aluminum branch circuit wiring
8.3 The inspector is NOT required to:
A. insert any tool, probe, or testing device inside the panels
B. test or operate any overcurrent device except Ground Fault
Circuit Interrupters
C. dismantle any electrical device or control other than to remove
the covers of the main and auxiliary distribution
panels
D. observe:
1. low voltage systems
2. smoke detectors
3. telephone, security, cable TV, intercoms, or other ancillary
wiring that is not a part of the
primary electrical distribution system
9.0 SYSTEM: HEATING
9.1 The inspector shall observe:
A. Permanently installed heating systems including:
1. heating equipment
2. normal operating controls
3. automatic safety controls
4. chimneys, flues, and vents
5. solid fuel heating devices
6. heat distribution systems including fans, pumps, ducts and
piping, with supports,
dampers, insulation, air filters, registers, radiators, fan-coil
units, convectors
7. the presence of an installed heat source in each room
9.2 The inspector shall:
A. describe:
1. energy source
2. heating equipment and distribution type
B. operate the systems using normal operating controls
C. open readily openable access panels provided by the manufacturer
or installer for routine homeowner maintenance
9.3 The inspector is NOT required to:
A. operate heating systems when weather conditions or other
circumstances may cause equipment damage
B. operate automatic safety controls.
C. ignite or extinguish solid fuel fires.
D. observe:
1. the interior of flues
2. fireplace insert flue connections
3. humidifiers
4. electronic air filters
5. the uniformity or adequacy of heat supply to the various rooms
10.0 SYSTEM: CENTRAL AIR
CONDITIONING
10.1 The inspector shall observe:
A. Central Air Conditioning including:
1. cooling and air handling equipment
2. normal operating controls
B. distribution systems including:
1. fans, pumps, ducts and piping, with supports, dampers,
insulation, air filters, registers
and fan-coil units
2. the presence of an installed cooling source in each room
10.2 The inspector shall:
A. describe:
1. energy sources.
2. cooling equipment type.
B. operate the systems using normal operating controls.
C. open readily openable access panels provided by the manufacturer
or installer for routine homeowner maintenance
10.3 The inspector is NOT required to:
A. operate cooling systems when weather conditions or other
circumstances may cause equipment damage.
B. observe non-central air conditioners
C. observe the uniformity or adequacy of cool-air supply to the
various rooms
11.0 SYSTEM: INTERIORS
11.1 The inspector shall observe:
A. walls, ceilings, and floors
B. steps, stairways, balconies, and railings
C. counters and a representative number of cabinets
D. a representative number of doors and windows
E. separation walls, ceilings, and doors between a dwelling unit and
an attached garage or another dwelling unit
F. sumps
11.2 The inspector shall:
A. operate a representative number of primary windows and interior
doors
B. report signs of water penetration into the building or signs of
abnormal or harmful condensation on building
components
11.3 The inspector is NOT required to observe:
A. paint, wallpaper, and other finish treatments on the interior
walls, ceilings, and floors
B. carpeting
C. draperies, blinds, or other window treatments
D. household appliances
E. recreational facilities or another dwelling unit
12.0 SYSTEM: INSULATION &
VENTILATION
12.1 The inspector shall observe:
A. insulation and vapor retarders in unfinished spaces
B. ventilation of attics and foundation areas
C. kitchens, bathroom, and laundry venting system
12.2 The inspector shall describe:
A. insulation and vapor retarders in unfinished spaces
B. absence of same in unfinished space at conditioned surfaces
12.3 The inspector is NOT required to report on:
A. concealed insulation and vapor retarders
B. venting equipment which is integral with household appliances
Glossary
Automatic Safety Controls:
Devices designed and installed to protect systems and components
from excessively high or low pressures and temperatures, excessive
electrical current, loss of water, loss of ignition, fuel leaks,
fire, freezing, or other unsafe conditions.
Central Air Conditioning:
A system which uses ducts to distribute cooled and/or dehumidified
air to more than one room or uses pipes to distribute chilled water
to heat exchangers in more than one room, and which is not plugged
into an electrical convenience outlet.
Component:
A readily accessible and observable aspect of a system, such as a
floor, or a wall, but not individual pieces such as boards or nails
where many similar pieces make up the component.
Cross Connection:
Any physical connection or arrangement between potable water and any
source of contamination.
Dangerous or Adverse Situations:
Situations which pose a threat of injury to the inspector, and those
situations which require use of special protective clothing or
safety equipment.
Describe:
Report in writing a system or component by its type, or other
observed characteristics, to distinguish it from other components
used for the same purpose.
Dismantle:
To take apart of remove any component, device or piece of equipment
that is bolted, screwed, or fastened by other means and that would
not be dismantled by a homeowner in the course of normal household
maintenance.
Engineering:
Analysis or design work requiring extensive preparation and
experience in the use of mathematics, chemistry, physics, and the
engineering sciences.
Enter:
To go into an area to observe all visible components.
Functional Drainage:
A drain is functional when it empties in a reasonable amount of time
and does not overflow when another fixture is drained
simultaneously.
Functional Flow:
A reasonable flow at the highest fixture in a dwelling when another
fixture is operated simultaneously.
Household Appliances:
Kitchen and laundry appliances, room air conditioners, and similar
appliances.
Inspector:
Any person who examines any component of a building, through visual
means and through normal user controls, without the use of
mathematical sciences.
Installed:
Attached or connected such that the installed item requires tools
for removal.
Normal Operating Controls:
Homeowner operated devices such as a thermostat, wall switch, or
safety switch.
Observe:
The act of making a visual examination.
On-site Water Supply Quality:
Water quality is based on the bacterial, chemical, mineral, and
solids content of the water.
On-site Water Supply Quantity:
Water quantity is the rate of flow of water.
Operate:
To cause systems or equipment to function.
Primary Windows and Doors:
Windows and/or exterior doors which are designed to remain in their
respective openings year round and not left open for the entire
summer.
Readily Openable Access Panel:
A panel provided for homeowner inspection and maintenance which has
removable or operable fasteners or latch devices in order to be
lifted off, swung open, or otherwise removed by one person, and its
edges and fasteners are not painted in place. Limited to those
panels within normal reach or from a 4-foot stepladder, and which
are not blocked by stored items, furniture, or building components.
Recreational Facilities:
Spas, saunas, steam baths, swimming pools, tennis courts, playground
equipment, and other exercise, entertainment, or athletic
facilities.
Representative Number:
For multiple identical components such as windows and electric
outlets -- one such component per room. For multiple identical
exterior components -- one such component on each side of the
building.
Roof Drainage Systems:
Gutters, downspouts, leaders, splashblocks, and similar components
used to carry water off a roof and away from a building.
Safety Glazing:
Tempered glass, laminated glass, or rigid plastic.
Shut Down:
A piece of equipment or a system is shut down when it cannot be
operated by the device or control which a homeowner should normally
use to operate it. If its safety switch or circuit breaker is in the
"off" position, or its fuse is missing or blown, the inspector is
not required to reestablish the circuit for the purpose of operating
the equipment or system.
Solid Fuel Heating Device:
Any wood, coal, or other similar organic fuel burning device,
including but not limited to fireplaces whether masonry or factory
built, fireplace inserts and stoves, wood stoves (room heaters),
central furnaces, and combination of these devices.
Structural Component:
A component which supports non-variable forces or weights (dead
loads) and variable forces or weights (live loads).
System:
A combination of interacting or interdependent components, assembled
to carry out one or more functions.
Technically Exhaustive:
An inspection is technically exhaustive when it involves the
extensive use of measurements, instruments, testing, calculations,
and other means to develop scientific or engineering findings,
conclusions, and recommendations.
Underfloor Crawl Space:
The area within the confines of the foundation and between the
ground and the underside of the lowest floor structural component.
CODE OF ETHICS
Honesty, justice and courtesy form a moral philosophy which,
associated with mutual interest among people constitutes the
foundation of ethics. The members should recognize such a standard,
not in passive observance, but as a set of dynamic principles
guiding their conduct. It is their duty to practice their profession
according to this code of ethics.
As the keystone of professional conduct is integrity, the members
will discharge their duties with fidelity to the public, their
clients and with fairness and impartiality to all. They should
uphold the honor and dignity of their profession and avoid
association with any enterprise of questionable character, or
apparent conflict of interest.
1. The member will express an opinion only when it is based on
practical experience and honest conviction.
2. The member will always act in good faith toward each client.
3. The member will not disclose any information concerning the
results of the inspection without the approval of the
clients or their representatives.
4. The member will not accept compensation, financial or otherwise,
from more than one interested party for the same service without the
consent of all interested parties.
5. The member will not accept nor offer commissions or allowances,
directly, from other parties dealing with their client in connection
with work for which the member is responsible.
6. The member will promptly disclose to his client any interest in a
business which may affect the client. The member will not allow an
interest in any business to affect the quality or results of their
inspection work which they may be called upon to perform. The
inspection work may not be used as a vehicle by the inspector to
deliberately obtain additional work in another field.
7. An inspector shall make every effort to uphold, maintain and
improve the professional integrity, reputation and
practice of the home inspection industry. He will report all such
relevant information, including violations of this Code by other
members, to the Association for possible remedial action.

Home,
What is a home
inspection, Seller Inspection,
Buyer Inspection,
Contact Info, Common Questions,
Inspection Agreement,
Radon,
Seasonal Maintenance Tips,
ASHI Standards,
Sell Your House, Recalls,
Site Map,
New Jersey Home
Inspector Committe |
Click
on picture

Memeber of
American Society of Home Inspectors

international Association of Certified Home
Inspectors

|